This document describes how to create a Boron Nitride mono-layer (Fig. 3b) and how to modify it replacing one or more atoms and adding atoms. BN has a layered structure that consists of rings of 3 B or 3 N atoms arranged in horizontal sheets (Fig. 1b).


Top
BN model

To create a BN model one has to select a single layer of BN groups. This is done in 2 steps by Make orthogonal (Fig. 1c) and To slices (Fig. 2).

  1. With the BN P 63mc crystal structure create an orthorhombic unit cell (Fig. 1d).

  2. Duplicate the orthorhombic unit cell 19 and 11 times in the x and y directions respectively to obtain a orthorhombic of large, nearly equal, a and b cell parameters (Fig. 2).

  3. The orthorhombic structure is described by BN_slices.txt file.

  4. Slicing the BN_slices.txt file in 3 sub-slices and the second sub-slice BN_0001.txt is the .txt model file.

Figure1a Figure1b

Figure 1a BN P 63mc.

Figure 1b BN layers.

Figure1c Figure1d

Figure 1c Make orthogonal defines an orthorhombic cell.

Figure 1d BN, orthorhombic description.

Figure2

Figure 2 To slices duplicates the cell in x and y directions.

Figure3a Figure3b

Figure 3a Slicing in 3 slices.

Figure 3b BN layer (second sub-slice).


Top
Popup imaging

With the popup menu attached to the model (Fig. 3b) the projected potential, HAADF, WPOA and SAED images are readlily calculated with the current settings of the microscope, aberrations, coherence, etc. (Figures 4a, 4b, 4c, 4d).

Figure4a Figure4b

Figure 4a Projected potential.

Figure 4b HAADF.

Figure4c Figure4d

Figure 4c WPOA image.

Figure 4d SAED.


Top
BF imaging

ADF images of the BN layer are obtained using the ADF imager. The simulations parameters are:

Each simulation run produces 4 Bright Field images with BF detector radius 10, 30, 50, 70 nm-1 (Figures 5a, 5b, 5c, 5d). With a negative W40 (C30) the first BF image is similar to the HRTEM image.

Figure5a Figure5b

Figure 5a BF outer radius 10 nm-1.

Figure 5b BF outer radius 30 nm-1.

Figure5c Figure5d

Figure 5c BF outer radius 50 nm-1.

Figure 5d BF outer radius 70 nm-1.


Top
DF imaging

Each simulation run produces also 4 Dark Field images with detector inner and outer radii 60 to 150, 80 to 170, 100 to 190, 120 to 210 nm-1 (Figures 6a, 6b, 6c, 6d). With a negative W40 (C30) the first BF image is similar to the HRTEM image.

Figure6a Figure6b

Figure 6a DF 60 to 150 nm-1.

Figure 6b DF 80 to 170 nm-1.

Figure6c Figure6d

Figure 6c DF 100 to 190 nm-1.

Figure 6d DF 120 to 210 nm-1.


Top
DPC imaging

4 sector detectors (1 to 4) are placed between the BF and DF detectors. By default the inner and outer radii of the sector detectors are set to the outer radius of the BF detector and the inner radius of the DF detector (Figures 7a, 7b, 7c, 7d).

Figure7a Figure7b

Figure 7a Sector 1.

Figure 7b Sector 2.

Figure7c Figure7d

Figure 7c Sector 3.

Figure 7d Sector 4.

Differential Phase Contrast imaging is an interesting feature of sector detectors. DPC images calculated using the sector images (Figures 7a, 7b, 7c, 7d) are shown below. Indeed these DPC images result of simulations, experimentally provided ones will most likely be somehow different due to non-uniformity of the detectors, etc. In spite of that simulated DPC images could provide valuable insights on the BN structure when it contains impurities like W.

Figure8a Figure8b

Figure 8a S1 + S2 + S3 + S4.

Figure 8b S1 + S2 - S3 - S4.

Figure8c Figure8d

Figure 8c S1 - S2 + S3 - S4.

Figure 8d -S1 + S2 - S3 + S4.

Figure9a Figure9b

Figure 9a S1 + S2 + S3 + S4.

Figure 9b -S1 - S2 + S3 + S4.

Figure9c Figure9d

Figure 9c S1 - S2 - S3 + S4.

Figure 9d -S1 + S2 + S3 - S4.


Top
HAADF imaging

As noted by K. Ishizuka, A practical approach for STEM image simulation based on the FFT multislice method, Ultramicroscopy 90 (2002) 71–83, it is not necessary for accurate calculations to scan the whole periodic model. Fig. 10a shows a HAADF image calculated with Ishizuka approach. The images shown in Figures 5, 6, 7, 8, 9 and 10a, were computed on a smaller part of the model of size 512 × 512 (Fig. 10a), with a probe shape shown in Fig. 10b. The projected potential was initialized on 1024 x 1024 grid with Weickenmeier-Kohl atomic form factors.

Figure10a Figure10b

Figure 10a HAADF Ishizuka method.

Figure 10b Scan area.

Figure10c Figure10d

Figure 10c Probe shape and profile.

Figure 10d Probe 3-D view.


Top
Detectors

During the scanning one can observe the power spectrum, bright field, dark field and 4 sectors detectors (12a, 12b, 12c, 12d).

Figure12a Figure12b

Figure 12a Power spectrum.

Figure 12b Bright field detector.

Figure12c Figure12d

Figure 12c Dark field detector.

Figure 12d 4 sectors detector.

Finally the probe wave-function is shown in Fig. 13.

Figure13

Figure 13 Probe wave-function (real and imaginary parts).


Top
Add on atoms

Adding or changing one atom can be done by modifying the BN layer using a text editor or the crystal Builder. When pointing to a B or N atom the builder will provide its fractional coordinates (Fig. 14).

Figure14

Figure 14 Pointing to an atom provides its fractional coordinates.